5.10.3
Example of the procedure to measure the kinematics (CYCLE996)
By way of illustration, the BC table kinematics measurement process (both rotary axes move
the workpiece) is described below:
● The two rotary axes can only be adjusted mechanically (workholder with orientation
● The computed values are archived in TCARR data.
General procedure
● Create/check TCARR data:
● Mount calibration ball on the clamping device
● Load and activate the probe in the spindle
● Calibrate the probe using CYCLE976 or "Calibrate probe". Measure in JOG mode
Procedure for approaching positions
Measuring cycles
Programming Manual, 03/2009 Edition, 6FC5398-4BP10-2BA0
capability)
MD 18088 MM_NUM_TOOL_CARRIER > = 1?
Measuring Cycles for Milling and Machining Centers
5.10 CYCLE996 workpiece: Measure kinematics
243