1.12.7
Measuring spheres
CYCLE997 permits correction of the zero offset after measurement of a sphere or of three
identically sized spheres on a common base (workpiece). Either paraxial measurement or
measurement at an angle can be selected.
Workpiece measurement: sphere
Result:
● Actual dimension: Actual position of center, diameter
● Deviation: Zero offset (for one sphere translation only, for three spheres also rotation in
Measuring cycles
Programming Manual, 03/2009 Edition, 6FC5398-4BP10-2BA0
space)
1.12 Overview of measuring cycle functions for milling technology
General
53