Use Program 31-02 : Internal Paging Group Assignment to assign extensions to Internal Paging
Program
Groups (i.e., Page Zones). The setting in this program also determines if the Internal Page Group can
receive Internal All Call Paging. The system can have up to 32 paging groups. An extension can be in
31
only one Internal Paging Group.
Input Data
Item
No.
01
Internal Paging Group
Number
02
Internal All Call Pag-
ing Receiving
Conditions
None
Feature Cross Reference
• Paging, Internal
2-324

31-02 : Internal Paging Group Assignment

Extension Number
Item
Input Data
0 ~ 32
(0 = No setting)
0 = Off
1 = On
Program 31 : Paging Setup
Maximum eight digits
Description
Assign extensions to Internal Paging
Groups (i.e., Page Zones). The system al-
lows up to 32 Internal Paging Groups. An
extension can be in only one Internal Pag-
ing Group.
Allow or prevent All Call Internal Paging for
each extension. If allowed, extension can
place and receive All Call Internal Paging
announcements. If prevented, extensions
can only make (not receive) All Call Inter-
nal Paging announcements. If combined,
Paging zones should be restricted as well,
change the internal page zone group in
Program 31-07-01 to 0.
ISSUE 6.0
Default
Port 1 ~ 16 = 1
(Group 1),
Port 17 ~ = 0
0
Program 31 : Paging Setup