Program 32 : Door Box And Sensor Setup; Door Box Timers Setup - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 6.0

Program 32 : Door Box and Sensor Setup

Level:
IN
Description
Use Program 32-01 : Door Box Timers Setup to assign the timers used for the Door Box.
The Door Box feature is called Door Phone when programming via WebPro and using a multiline terminal.
Input Data
Item
Item
No.
01
Door Box Answer
Time
02
Door Lock Cancel
Time
03
Off-Premise Call For-
ward by Door Box
Disconnect Timer
Conditions
None
Feature Cross Reference
• Door Box
Programming Manual

32-01 : Door Box Timers Setup

Input Data
0 ~ 64800 seconds
A user can answer the door box during the
time specified in this program.
0 ~ 64800 seconds
When a user activates the door lock re-
lease relay, this program specifies the
amount of time the door strike remains
open.
0 ~ 64800 seconds
Define the conversation period for an Off-
Premise Call Forward by Door Box call.
When this timer expires, the caller hears
busy tone for three seconds (fixed time),
and the call is then disconnected.
Description
SL1100
Program
32
Default
30 seconds
10 seconds
60 seconds
2-333