Ring Cycle Setup; Table 2-5 Ringing Cycles - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Level:
IN
Description
Use Program 20-15 : Ring Cycle Setup to define the ringing cycles for each ring type.
Program
20
Input Data
Item
No.
01
Incoming Signal Type : Normal In-
coming Call on Trunk
02
Incoming Signal Type : PBX, CES
Incoming Call
03
Incoming Signal Type : Incoming
Internal Call
04
Incoming Signal Type : DID/
DISA/VRS
05
Incoming Signal Type : DID/DDI
06
Incoming Signal Type : Dial-In in
the E&M Tie Line
07
Incoming Signal Type : Door Box
Ringing for SLT
08
Incoming Signal Type : Virtual Ex-
tension Ring
09
Incoming Signal Type : Callback
10
Incoming Signal Type : Alarm for
SLT
11
Incoming Signal Type : VRS Wait-
ing Message Incoming Call
Number
1
2
3
4
5
6
7
8
9
10
2-194
Program 20 : System Option Setup
Item
Ringing Cycle Number : 1 ~ 13
Ringing Cycle Number : 1 ~ 13
Ringing Cycle Number : 1 ~ 13
Ringing Cycle Number : 1 ~ 13
Ringing Cycle Number : 1 ~ 13
Ringing Cycle Number : 1 ~ 13
Ringing Cycle Number : 1 ~ 13
Ringing Cycle Number : 1 ~ 13
Ringing Cycle Number : 1 ~ 13
Ringing Cycle Number : 1 ~ 13
Ringing Cycle Number : 1 ~ 13

Table 2-5 Ringing Cycles

On
On : 2.0 / Off : 4.0
On : 1.0 / Off : 2.0
On : 0.5 / Off : 0.5
On : 0.25 / Off : 0.25
On : 0.5 / Off : 0.5 / On : 0.5 / Off : 1.5
On : 0.25 / Off : 0.25 / On : 0.25 / Off : 5.25
On : 0.375 / Off : 0.25 / On : 0.375 / Off : 2.0
On : 0.25 / Off : 0.125 / On : 0.25 / Off : 0.125 / On : 0.25 / Off : 2.0
On : 1.0 / Off : 4.0

20-15 : Ring Cycle Setup

Input Data
Ringing Cycle
Program 20 : System Option Setup
ISSUE 6.0
Default
2
8
12
8
8
12
8
8
11
5
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents