NEC SL1100 Programming Manual page 431

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 6.0
Item
Item
No.
17
InMail Port
18
Play PAD Control
19
Record PAD Control
(for Networking)
Conditions
• When changing 47-01-01 or 47-01-02, a system reset is required for the new setting to take effect.
Feature Cross Reference
None
Programming Manual
Input Data
0 ~ 113 (V3.5 Changed)
When using V3.5 or higher software the In-
(Can only use the port
Mail can be assigned to ports 113-128 and
numbers provided in the
will not affect the total station and trunk
description section.)
ports. In addition when the SL1100 is de-
faulted with an InMail CF mounted the In-
Mail is automatically assigned to ports
113-128 and when a SL1100 is upgraded
to V3.5 or higher software the InMail ports
can be moved to 113-128.
The first port of InMail must start with one
of the following ports:
5, 9, 13, 17, 21, 25, 29, 33, 37, 41, 45, 49,
53, 57, 61, 65, 69, 73, 77, 81, 85, 89, 93,
97, 101, 105, 109, 113. Only able to set
61~113 with V3.5 or higher.
1 ~ 63
(- 15.5 dBm ~ + 15.5
dBm)
1 ~ 63
(- 15.5 dBm ~ + 15.5
dBm)
Description
SL1100
Default
0
Program
32
47
32
2-411