Dr700 Multiline Basic Information Setup - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Level:
IN
Description
Use Program 84-23 : DR700 Multiline Basic Information Setup to set the basic information for the
Program
DR700 Multiline Terminal.
84
Input Data
Item
No.
01
Registration Expire
Timer
02
Subscribe Expire Tim-
er
03
Session Expire Timer
04
Minimum Session Ex-
pire Timer
05
Invite Expire Timer
06
Signal Type of Serv-
ice
07
Error Display Timer
08
Digest Authorization
Registration Expire
Timer
09
Temporally Password
(V3.5 Deleted)
10
Number of Password
Retries
11
Password Lock Time
12
Reference Number
13
Media Type of Service 0x00 ~ 0xFF
2-514
Program 84 : Hardware Setup for VoIPDB

84-23 : DR700 Multiline Basic Information Setup

Item
Input Data
60 ~ 65535 seconds
60 ~ 65535 seconds
60 ~ 65535 seconds
60 ~ 65535 seconds
60 ~ 65535 seconds
0x00 ~ 0xFF
(0 ~ 9, A ~ F)
0 ~ 65535 seconds
0 ~ 4294967295 sec-
onds
Read Only:
Maximum 16 characters
(0 ~ 9, a ~ f, A ~ F)
0 ~ 255
(0 = No Limit)
0 ~ 120
(0 = No Limit)
Up to 32 digits
(0 ~ 9,
*
, #, P, R, @)
(0 ~ 9, A ~ F)
Description
The Expires value of the REGISTER mes-
sage which received from DR700 terminal
is out of range or when the Expire value is
not set up, in case it assigns the effective
time to the DR700 terminal. The timer for
supervising whether DR700 terminal is
connected or not.
The subscribe Expire timer to transmit and
receive the terminal operation instructions
between the Main Device and DR700 ter-
minal.
Set effective time for supervising the Voice
Path.
Set minimum value of effective time for su-
pervising the Voice Path.
Set effective time for Incoming/Outgoing
call when the Expire value is not set in the
INVITE message received from DR700
terminal.
Set Type of Service value which applied to
send SIP Message Packet from DR700
terminal to Main Device.
Input the number of times an incorrect
password can be entered when the securi-
ty key is pressed.
Program 84 : Hardware Setup for VoIPDB
ISSUE 6.0
Default
180 seconds
3600 seconds
180 seconds
180 seconds
180 seconds
00
0
0
None
0
0
No Setting
00