ISSUE 2.0
Level:
IN
Description
Use Program 31-02 : Internal Paging Group Assignment to assign extensions to Internal Paging
Groups (i.e., Page Zones). The setting in this program also determines if the Internal Page Group can
receive Internal All Call Paging. The system can have up to 50 paging groups. An extension can be in
only one Internal Paging Group.
Input Data
Extension Number
Item
Item
No.
01
Internal Paging
Group Number
02
Internal All Call
Paging Receiv-
ing
Conditions
None
Feature Cross Reference
• Paging, Internal
Programming Manual
Program 31 : Paging Setup
31-02 : Internal Paging Group Assignment
Input Data
0 ~ 50
Assign extensions to Internal Paging
(0 = No Setting)
Groups (i.e., Page Zones). The sys-
tem allows up to 50 Internal Paging
Groups. An extension can be in only
one Internal Paging Group.
0 = Off
Allow or prevent All Call Internal
1 = On
Paging for each extension. If al-
lowed, extension can place and re-
ceive All Call Internal Paging an-
nouncements. If prevented, exten-
sions can only make (not receive)
All Call Internal Paging announce-
ments. If combined, Paging zones
should be restricted as well, change
the internal page zone group in Pro-
gram 31-07-01 to 0.
Maximum eight digits
Description
Default
Port 1 ~ 16 = 1
(Group 1),
Port 17 ~ = 0
SL2100
Program
31
Related
Program
0
31-02-01
2-355