NEC SL1100 Programming Manual page 547

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 6.0
Item
Item
No.
28
RTP Tx Level
Control
29
RTP Tx Level
Control Level
30
RTP Tx Automa-
ticLevelControl
Level (V2.0 Add-
ed)
31
RTP Tx HLC
Threshold
32
RTP Tx Gain
Compression
mode
33
RTP Tx Gain
Compression
Threshold
34
RTP Rx Level
Control (V2.0
Added)
35
RTP Rx Level-
Control Level
(V2.0 Added)
Programming Manual
Input Data
0 = Disable
1 = Tx Level Control
mode (V5.0 Changed)
2 = Tx Automatic Level
Control mode (V5.0
Changed)
3 = HLC
0 ~ 16 (- 24 ~ 24 dB)
0 = - 24 dB
1 = - 21 dB
2 = - 18 dB
:
8 = 0 dB
:
14 = 18 dB
15 = 21 dB
16 = 24 dB
0 ~ 12 (- 42 dbm ~ - 6
Do not change the setting unless
dbm)
asked to change by engineer. (V5.0
0 = - 42 dBm
Deleted)
1 = - 39 dBm
Select target gain. (V5.0 Deleted)
:
Effective when PRG 84-31-28 = 2
7 = - 21 dBm
(V5.0 Deleted)
:
11 = - 9 dBm
12 = - 6 dBm
0 ~ 42 (- 42 dBm ~ 0
dBm)
0 = - 42 dBm
1 = - 41 dBm
:
42 = 0 dBm
0 = Disable
1 = Enable
0 ~ 42 (- 42 dBm ~ 0
dBm)
0 = - 42 dBm
1 = - 41 dBm
:
42 = 0 dBm
0 = Disable
Do not change the setting unless
1 = RX Level Control
asked to change by engineer. (V5.0
Mode
Deleted)
2 = RX Automatic Level
Select receive level control mode.
Control
(V5.0 Deleted)
Flag
0 ~ 16 (- 24 dB ~ + 24
Do not change the setting unless
dB)
asked to change by engineer. (V5.0
0 = - 24 dB
Deleted)
1 = - 21 dB
Select receive voice level. (V5.0 De-
:
leted)
8 = 0 dB
Effective when PRG 84-31-34 = 1
:
(V5.0 Deleted)
15 = 21 dB
16 = 24 dB
Description
Default
Type 1, Type 7 ~
8 = 3 (V1.5
Changed)
Type 9, 11~15 =
Type 18 = 3
(V5.0 Added)
Type 1, Type 7 ~
8 = 36 (V1.5
Changed)
Type 9, 11~15 =
Type 18 = 36
(V5.0 Added)
Type 1, Type 7 ~
8 = 1 (V1.5
Changed)
Type 9, 11~15 =
Type 18 = 1
(V5.0 Added)
Type 1, Type 7 ~
8 = 36 (V1.5
Changed)
Type 9, 11~15 =
Type 18 = 36
(V5.0 Added)
SL1100
Related
Program
0
8
Program
84
7
84-31-28
42
0
42
0
8
84-31-34
2-527

Hide quick links: