Program 81 : Basic Hardware Setup for Trunk

Level:
IN
Description
Use Program 81-01 : CO Initial Data Setup to define the various basic data parameters for the
COIU.
Input Data
Item
Item
No.
01
PCM Encoding Method Specifica-
tion
02
Loop Current Detection Time
03
Clear Signal (Open Loop) Detec-
tion Time
04
Ringing Signal Detection Minimum
Time
05
Single Ringing Detection Minimum
Time
06
Double Ringing Detection Mini-
mum Off Time
07
Double Ringing Detection Maxi-
mum Off Time
08
Ringing Signal not Detection Mini-
mum
09
Time Ringing Signal Stop Detec-
tion Time
10
Continuous Ringing Minimum
Time
11
Continuous Ringing Maximum
Time
14
Hook Flash 1 Time
15
Hook Flash 2 Time
16
Pause Time
17
PFT Idle Detection Time
20
Loop Reverse Detect Minimum
Time
21
Loop Reverse Detect Maximum
Time
22
Loop Disconnect Detect Minimum
Time
Programming Manual

81-01 : CO Initial Data Setup

Input Data
0 = μ-law
1 = A-law
1 ~ 255
(10 ~ 2550 ms)
1 ~ 255
(5 ~ 1275 ms)
1 ~ 255
(10 ~ 2550 ms)
0 ~ 255
(0, 10 ~ 2550 ms)
0 ~ 255
(0, 10 ~ 2550 ms)
0 ~ 255
(0, 10 ~ 2550 ms)
1 ~ 255
(10 ~ 2550 ms)
1 ~ 255
(100 ~ 25500 ms)
0 ~ 255
(0, 10 ~ 2550 ms)
0 ~ 255
(0, 10 ~ 2550 ms)
1 ~ 255
(10 ~ 2550 ms)
1 ~ 255
(100 ~ 25500 ms)
1 ~ 255
(100 ~ 25500 ms)
1 ~ 255
(100 ~ 25500 ms)
1 ~ 255
(10 ~ 2550 ms)
1 ~ 255
(10 ~ 2550 ms)
1 ~ 255
(10 ~ 2550 ms)
SL1100
Program
81
Default
0 (μ-law)
60 (600 ms)
61 (305 ms)
10 (100 ms)
66 (660 ms)
10 (100 ms)
40 (400 ms)
70 (700 ms)
60 (6000 ms)
30 (300 ms)
70 (700 ms)
80 (800 ms)
25 (2500 ms)
10 (1000 ms)
30 (3000 ms)
10 (100 ms)
86 (860 ms)
40 (400 ms)
2-467