ISSUE 6.0
Level:
IN
Description
Use Program 20-28 : Trunk to Trunk Conversation to define system options for Trunk to Trunk
Conversation.
Input Data
Item
Item
No.
01
Conversation
Continue Code
02
Conversation
Disconnect Code
03
Conversation
Continue Time
Conditions
None
Feature Cross Reference
None
Programming Manual
Program 20 : System Option Setup
20-28 : Trunk to Trunk Conversation
Input Data
0 ~ 9,
*
, #
Input the code that can be dialed to
(Set for one digit only)
continue the conversation after the
Trunk-to-Trunk Release Warning
Tone is heard.
0 ~ 9,
*
, #
Input the code that can be dialed to
(Set for one digit only)
disconnect the conversation after
the Trunk-to-Trunk Release Warning
Tone is heard.
0 ~ 64800 seconds
Input how long the conversation ex-
tends when the Conversation Con-
tinue Code is dialed.
Description
Default
No Setting
No Setting
SL1100
Program
20
Related
Program
14-01-25
20-28-03
24-02-07
24-02-10
25-07-07
25-07-08
14-01-25
24-02-07
24-02-10
25-07-07
25-07-08
0
14-01-25
20-28-01
24-02-07
24-02-10
25-07-07
25-07-08
2-207