Dial-In Conversion Table Area Setup For Time Pattern - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Level:
SA
Description
Program
Use Program 22-17: Dial-In Conversion Table Area Setup for Time Pattern to define Time Zone
and Dial-In Conversion Table (Program 22-11) for Time Pattern.
22
Input Data
Item
No.
01
Received Dial
02
Start of Time
03
End of Time
04
Dial-In Conversion Ta-
ble Number
05
Day of week (V2.0
Added)
Conditions
None
Feature Cross Reference
None
2-276
Program 22 : Incoming Call Setup
22-17 : Dial-In Conversion Table Area Setup for Time
Conversion Table Number
Time Pattern Number
Item
Input Data
Up to eight digits
0000 ~ 2359 (Time)
0000 ~ 2359 (Time)
1 ~ 800 (These are the
table entries in PRG
22-11.)
1: Sun
2: Mon
3: Tue
4: Wed
5: Thu
6: Fri
8: Sun
9: Holiday
0 = Off
1 = On
001 ~ 500 (V2.0 Changed)
1 ~ 8
Description
Define the Starting Time for each DID
Translation table in PRG 22-17-01.
Define the Ending Time for each DID
Translation table in PRG 22-17-01.
Assign Day of Week for each DID conver-
sion table.
Program 22 : Incoming Call Setup
ISSUE 6.0
Pattern
Default
No Setting
0000
0000
0
1

Hide quick links: