Program 82 : Basic Hardware Setup for
Level:
IN
Description
Use Program 82-11 : SLIU Initial Data Setup to define the various timers for SLIU.
Input Data
Item
Item
No.
01
Bounce Protect Time
02
HookFlash Start Time
03
HookFlash End Time
Conditions
None
Feature Cross Reference
None
Programming Manual

82-11 : SLIU Initial Data Setup

Input Data
0 = No setting
Specify a time for detection of a valid off-
1 ~ 15 = 100 ms ~ 1.5
Hook indication that is long enough to pre-
sec
vent an unintentional bounce of the receiv-
er from being detected as a new Off-Hook
indication from a Single Line Telephone.
0 = 40 ms
Specify the minimum hookflash time from
1 ~ 15 = 90 ms ~ 790 ms
a Single Line Telephone or analog Voice
Mail system before it is detected as the be-
ginning of a valid hookflash.
0 = HST + 0 ms
Specify the maximum hookflash duration
1 ~ 15 = HST + 100 ms
from a Single Line Telephone to receive a
~ HST + 1500 ms
second dial tone.
(HST = Hookflash Start
Time)
Extension
Description
SL1100
Program
82
Default
3
(300 ms)
5
(290 ms)
7
(990 ms)
2-489