Conditions
None
Feature Cross Reference
• ISDN Compatibility
Programming Manual
Input Data
1 ~ 254 seconds
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SETUP is sent or re-sent on broadcast da-
ta link. This timer is only valid for Network
side use only.
1 ~ 254 seconds
Specifies the timer value in 1/100ths of a
second of the timer to be started when
connection request is sent. Valid range 1 ~
4 seconds in 1 second increments. Value
of 0 indicates timer not used.
1 ~ 254 seconds
Specifies the timer value in 1/100ths of a
second of the timer to be started when
message segment is received.
(T317 + 1) ~ 254 sec-
Specifies the timer value in 1/100ths of a
onds
second of the timer to be started when RE-
START is sent.
1 ~ (T316-1)
Specifies the timer value in 1/100ths of a
second of the timer to be started when RE-
START is received.
1 ~ 254 seconds
Specifies the timer value in 1/100ths of a
second of the timer to be started when
RES is sent. This timer is valid for user
side use only.
1 ~ 254 seconds
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SUSPEND is sent. This timer is valid for
user side use only.
1 ~ 254 seconds
Specifies the timer value in 1/100ths of a
second when B-channel access: connec-
tion is received or D-channel access: DL-
ESTABLISH confirmation or indication is
received.
1 ~ 254 seconds
Specifies the timer value in 1/100ths of a
second of the timer to be started when
STATUS ENQ is received.
1 ~ 254 seconds
Specifies the timer value in 1/100ths of a
second upon D-channel failure.
Description
SL1100
Default
6
4
4
Program
120
81
60
4
4
30
30
4
2-471