Table 42 Informational events (continued)
Value
Informational event
0x12
Power on init done
0x13
Incorrect key server token PIN entered
0x14
Backup initiated on key server token
0x15
Backup off key server token finished
0x16
A new write key was automatically generated on
the key server token.
0x17
A new write key was manually generated on the
key server token.
0x18
More than 5 invalid key server token PIN attempts
0x19
Restore initiated on key server token
0x1A
Restore off key server token finished
0x1B
Key server token is over 90% full
0x1C
Key server token contains keys that have not been
backed up.
0x31
Proactive support ticket retrieval skipped.
0x32
Could not reach SNTP server.
0x33
Control path failover reported.
0x34
Data path failover reported
0x35
Drive generation less than LTO-5. LTFS not
supported.
0x36
Proactive support ticket retrieval skipped.
Using Library & Tape Tools to diagnose problems
With Library & Tape Tools installed on the host server you can:
Identify all parallel SCSI devices connected to your system.
View detailed configuration, identification, inventory, and drive information for the device.
Easily update device and drive firmware.
Run advanced diagnostic tests, including connectivity, read/write, media validation, and
testing the functionality of the device.
Description
Power on init completed successful
Incorrect key server token PIN entered
Incorrect key server token PIN entered
The backup of the key server token has finished.
A new write key was automatically generated on
the key server token.
A new write key was manually generated on the
key server token.
More than five attempts were made to set the key
server token with invalid PINs.
A restore operation was initiated on the key server
token.
A restore operation was completed on the key
server token.
The key server token is over 90% full.
The key server token contains keys that have not
been backed up.
The library will not pull a support ticket when it does
not have the resources to do so. Subsequent
tickets will contain the information needed for
analysis.
The configured SNTP server could not be reached.
Synchronization with the time server is not
possible.
A control path failover event occurred. The master
drive was successfully switched to the alternate
master drive.
A data path failover event occurred. The active
port was successfully changed to the previous
standby port.
LTFS is not supported with the current
configuration. LTFS requires LTO-5 or later
generation drives and media.