Table 31 Main error codes (continued)
Error code
D7
D8
D9
DA
DC
E0
162 Troubleshooting
Description
Firmware upgrade error
Library controller data base error
No SCSI IC detected
When running the wellness test, the bar code
did not match the previous value for that tape
I2C Bus failure.
Incompatible magazine detected. The mailslot
was enabled with a different mailslot magazine
type than is currently in the library. For example,
the mailslot was enabled with a three-slot
mailslot magazine and then the lower-left
Details and solution
This error can occur is an attempt is made to
upgrade a drive with the wrong personality or
version for that drive.
Ensure that the correct drive firmware is
being used to update the drive.
If the correct drive firmware is being used,
update the library firmware.
Power cycle the device and attempt the
operation again.
Power-cycle the unit.
Check the bar code label for proper
application and damage.
Run the wellness test again.
Power-cycle the device.
On the MSL4048, MSL8048, and MSL8096,
power off the library and re-seat the library
controller from the back panel.
Either replace the lower left magazine with
the original magazine, or disable and
re-enable the mailslot to reconfigure the
library with the new mailslot configuration.