Field Service Ver. 1.0 Jun. 2008
18. Power supply trouble
18.1 Machine is not energized at all (DCPU operation check)
Main power switch (SW1)
Front door switch/1 (MS3)
Front door switch/2 (MS4)
Printer control board (PRCB)
Step
Is a power voltage supplied across
1
CN1_INP-1 and 2 on DCPU?
2
Are the fuses on DCPU conducting?
Is DC24 V being output from CN_SIG-1 on
3
DCPU?
Is DC5 V being input to CN_MCB-5 and 7
4
on DCPU?
Is DC5 V being input to CN26-4 on PRCB?
5
(LED on PRCB does not blink.)
18.2 Control panel indicators do not light.
BCRU board (BCRUB)
OPEU board (OPEUB)
LCD board (LCDB)
LCD_INV board (LCDINVB)
Step
Is the I/F cable between the scanner and
1
engine connected properly?
Is a power voltage being applied across
2
CN_SCN1-8 on DCPU?
3
Is the fuse on DCPU conducting?
Is CN12 on MFBUB to CN2 on BCRUB
4
securely connected?
Is CN3 on BCRUB to CN1 on OPEUB
5
securely connected?
Relevant parts
Check item
Relevant parts
Check item
18. Power supply trouble
DC power supply (DCPU)
WIRING
DIAGRAM
Result
(Location)
Check the wiring from the
T-3
NO
wall outlet to SW1 to
CN1_INP.
—
NO
Change DCPU.
R-3 to 4
NO
Change DCPU.
R-4 to 5
NO
Change DCPU.
NO
Change DCPU.
H to I-3 to 4
YES
Change PRCB.
MFBU board (MFBUB)
DC power supply (DCPU)
WIRING
DIAGRAM
Result
(Location)
Reconnect or change the
—
NO
I/F cable.
Check the wiring from the
R-3
NO
wall outlet to SW1 to
CN_SCN1.
—
NO
Change DCPU.
V-6
NO
Reconnect.
W-19
W-17 to 18
NO
Reconnect.
U to V-17 to 18
Action
Action
315