Software Switch Setting - Konica Minolta bizhub C200 Service Manual

Hide thumbs Also See for bizhub C200:
Table of Contents

Advertisement

Field Service Ver. 1.0 Jun. 2008
10.5.10

Software Switch Setting

Functions
• To change the status of each function by setting values (mode, bit, HEX) for soft
switch of the machine as necessary.
Use
• Refer to the corresponding item on [Admin.] for the list of the soft switches available
of setting by the user (administrator).
See P.141
• For details of the software switch for fax settings, refer to the FK-507 service manual.
See P.20 of the FK-507 service manual.
Setting/
1. Call the Service Mode on the screen.
2. Touch [System Input] → [Software Switch Setting].
Procedure
3. Touch [Mode Selection], and enter the mode number (three digit number) using the
10-key pad.
4. Touch [Bit Selection].
5. Set the cursor using [←] or [→] key, and set the bit with 0 or 1 on the 10-key pad.
(When setting in hexadecimal, press [HEX Selection], and enter on the 10-key pad
or A to F keys.)
6. Touch [Apply].
7. Touch [OK].
A. Software Switch
Mode
Bit
HEX
B. List of the software switch settings
Mode
000
• TSI, password, memory TX
001
• Dest. insert
002
• Report
003
• Broadcast TX result report
004
• Memory time
005
• Default country setting
006
(Not used)
007
• G3-1 non-selectable cassette
008
• G3-2 non-selectable cassette
009
• Network non-selectable cassette
010
• Report non-selectable cassette
011
(Not used)
012
(Not used)
013
• Automatically switch destinations, operation when INBOX forward fails
• Each parameter is expressed as a three-digit number.
Use the keypad to type in the value.
• The bits are the eight numbers that represent the parameter status.
By specifying a binary number (0 or 1) for each of the bits (0 through 7), set-
tings for each parameter can be specified.
• Specify a setting for each mode as a hexadecimal number (0 through 9 and A
through F). Bit setting "0011 0000" is expressed as the hexadecimal setting
"30."
• Specify the status of each parameter by using either bits or hexadecimal val-
ues.
Setting item
10. Service Mode
Ref. page
173