15. Power supply trouble

15. Power supply trouble

15.1 Machine is not Energized at All (PU1 Operation Check)

Main Power Switch (S1)
Mechanical Control Board (PWB-M)
Step
Is a power voltage supplied across
1
CN1PU1-1 and 2 on PU1?
2
Are the fuses on PU1 conducting ?
Is DC3.3 V being output from CN6PU1-1 on
3
PU1?
Is "Low" being output from CN7PU1-2 on
4
PU1?
Is DC24 V being output from CN5PU1-2 on
5
PU1?
6
Is DC5 V being input to CN5PU1-3 on PU1?
Is DC5 V being input to CNPOW-2 on the
5
Control Board? (LED on PWB-M does not
blink.)
210
Relevant Electrical Parts
Check Item
Field Service Ver. 1.0 May 2006
DC Power Supply (PU1)
WIRING
DIAGRAM
Result
(Location)
Check the WIRING from
S to T-2
NO
the wall outlet to S1
CN1PU1.
NO
Change PU1.
R-4
NO
Change PU1.
Check the WIRING from
R-5
NO
the PWB-P to PWB-M to
CN1PU1.
R-6
NO
Change PU1.
R-4
NO
Change PU1.
NO
Change PU1.
I-6
YES
Change PWB-M
Action