Main Unit Field Service
3.

Power Supply Troubles

3.1

Machine is Not Energized at All (LV Operation Check)

Power Switch
Mechanical Control Board (PWB-A)
Step
Check Item
Is the power source voltage being applied to
1
CN1LV on LV?
2
Are fuses (F1 and F2) on LV conducting?
Are DC24 V and DC5 V being applied to
3
CN5V on the Mechanical Control Board?
3.2

Control panel indicators do not Light

Print Control Board (PWB-P)
Control Panel (PWB-OP)
Step
Check Item
Is the power source voltage being applied to
1
CN1LV on LV?
2
Are fuses (F1 and F2) on LV conducting?
3
Is CN10P on PWB-P properly connected?
4
Is CN20P on PWB-OP properly connected?
Relevant Electrical Parts
Low Voltage Unit (LV)
Location
(Electrical
Component)
12-L
-
10-K∼L
Relevant Electrical Parts
Low Voltage Unit (LV)
Location
(Electrical
Component)
12-L
-
14-B
11-E∼F
4-27
Power Supply Troubles
Result
Action
Check wiring from
NO
power outlet to PG1 to
CN1LV.
NO
Change LV.
NO
Change LV.
YES
Change PWB-A.
Result
Action
Check wiring from
NO
power outlet to PG1 to
CN1LV.
NO
Change LV.
NO
Reconnect.
NO
Reconnect.
Change PWB-OP.
YES
Change PWB-P.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magicolor 5440 dlMagicolor 5450

Table of Contents