Field Service Ver. 1.0 Jun. 2008
6.2.3
C11A1: Exit roller pressure/retraction failure
Roller pressure/retraction clutch (CL1)
Pressure/retraction home sensor (PS5)
Step
Check the CL1 connector for proper con-
1
nection and correct as necessary.
Check the connector of CL1 for proper
2
drive coupling and correct as necessary.
3
PS5 I/O check, sensor check
4
CL1 operation check
5
Change JSCB
6.2.4
C11E0: Finisher route change failure
Route change motor (M3)
Route change home sensor (PS4)
Step
Check the M3 connector for proper con-
1
nection and correct as necessary.
Check the connector of M3 for proper
2
drive coupling and correct as necessary.
3
PS4 I/O check, sensor check
4
M3 operation check
5
Change JSCB
Relevant electrical parts
JS control board (JSCB)
Action
Relevant electrical parts
JS control board (JSCB)
Action
6. Malfunction code
WIRING DIAGRAM
Control signal
—
—
JSCB PJ7-12 (ON)
JSCB PJ6-4 (ON)
—
WIRING DIAGRAM
Control signal
—
—
JSCB PJ7-12 (ON)
JSCB PJ6-4 (ON)
—
Location
(Electrical
component)
—
—
JS-505 F-4
JS-505 F-5
—
Location
(Electrical
component)
—
—
JS-505 F-4
JS-505 F-5
—
25