Konica Minolta bizhub C200 Service Manual page 279

Hide thumbs Also See for bizhub C200:
Table of Contents

Advertisement

10. Service Mode
Mode
485
State
Bit
7-6 Select order of displaying year to date.
(Corresponding to each region)
Order of displaying date in operation panel
display
Mode
486
State
Bit
6
Enables/Disables summer time mode.
Mode
487
State
Bit
1
Set "No sleep"
Mode
488
State
Bit
7-0 Auto reset
Select whether to carry out auto reset if there
is no operation for a certain time, after copy or
other operation. Also, select its time.
Every 1 min.
240
Default value
Bit
7654 3210
0000 0000 (for Europe)
1100 0000 (for U.S)
Setting item
Default value
Bit
7654 3210
0100 0000
Setting item
Default value
Bit
7654 3210
0000 0000
Setting item
Default value
Bit
7654 3210
0000 0001
Setting item
Field Service Ver. 1.0 Jun. 2008
HEX: 00 (for Europe)
HEX: C0 (for U.S)
Setting value
0
1
00
Year-Month-Date
01
Not available
10
Date-month-year
11
Month-date-year
HEX: 40
Setting value
0
1
Disable
Enable
HEX: 00
Setting value
0
1
No
Yes
HEX: 01
Setting value
0
1
0000 0000
0
0000 0001
1 min.
:
1111 0000
240 min.
:
1111 1111
30 sec.
others
Not available
Description
Description
Description
Description

Hide quick links:

Advertisement

Table of Contents
loading