Konica Minolta bizhub C200 Service Manual page 335

Hide thumbs Also See for bizhub C200:
Table of Contents

Advertisement

17. Malfunction code
• The machine displays an abort code on the control panel as it becomes unable to pro-
cess tasks properly through its software control.
• When the system program is aborted, the machine attempts to restart it automatically. If
it fails to restart the program, check or replace the electrical components, units, options,
and connections related to the specific type of abort condition.
Code
0x00000000 to 0x000fffff
0x00100000 to 0x001fffff
0x00200000 to 0x002fffff
0x00300000 to 0x003fffff
0x00500000 to 0x005fffff
0x00600000 to 0x006fffff
0x00700000 to 0x007fffff
0x00800000 to 0x008fffff
0x00900000 to 0x009fffff
0x00c00000 to 0x00c0ffff
0x00c10000 to 0x00c2ffff
0x00c30000 to 0x00c4ffff
0x00c50000 to 0x00c5ffff
0x00d00000 to 0x00d3ffff
0x00d80000 to 0x00dbffff
0x00dc0000 to 0x00dfffff
0x00e00000 to 0x00e000ff
0x00e00100 to 0x00e001ff
0x00e00200 to 0x00e002ff
0x00e00300 to 0x00e003ff
0x00e00400 to 0x00e004ff
0x00f00000 to 0x00f0ffff
0x00f20000 to 0x00f2ffff
0x01100000 to 0x011000ff
0x01100100 to 0x011001ff
0x01100400 to 0x011004ff
0x02000000 to 0x020fffff
0x03000000 to 0x030fffff
296
Item
OS processing system failure
Device control system failure
Copy control system failure
Operation system failure
Conversion processing system
failure
Encoding processing system failure • MFBUB, MEMU/1, MEMU/2
File control system failure
G3 protocol processing system
failure
G3 device control system failure
Scanner control system failure
Scanner control system failure
Scanner control system failure
Scanner control system failure
Scanner device control system
failure
Scanner device control system
failure
Scanner device control system
failure
Printer sequence system failure
Printer sequence system failure
Printer sequence system failure
Printer sequence system failure
Printer sequence system failure
Printer system failure
Counter sequence system failure
Other failures
Copy sequence system failure
Function sequence system failure
OS message processing system
failure
Network processing system failure • MFBUB, MEMU/1, MEMU/2
Field Service Ver. 1.0 Jun. 2008
Relevant electrical
components, units, and options
• MFBUB
• MFBUB, FAXUB, MEMU/1,
MEMU/2, job separator
• MFBUB
• MFBUB, control panel
• MFBUB
• MFBUB, MEMU/1, MEMU/2
• MFBUB, FAXUB, MEMU/1,
MEMU/2
• MFBUB, FAXUB, MEMU/1,
MEMU/2
• MFBUB, BCRUB, INVB, ADF
• MFBUB, BCRUB, INVB, ADF
• MFBUB, BCRUB, INVB, ADF
• MFBUB, BCRUB, INVB, ADF
• MFBUB, BCRUB, INVB
• MFBUB, BCRUB, INVB, ADF
• MFBUB, home position sensor,
scanner drive system, BCRUB
• MFBUB, MEMU/1, MEMU/2
• MFBUB, MEMU/1, MEMU/2
• MFBUB, MEMU/1, MEMU/2
• MFBUB, MEMU/1, MEMU/2
• MFBUB, MEMU/1, MEMU/2
• MFBUB, MEMU/1, MEMU/2
• MFBUB
• MFBUB
• MFBUB
• MFBUB
• MFBUB, MEMU/1, MEMU/2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents