Konica Minolta bizhub C200 Service Manual page 486

Hide thumbs Also See for bizhub C200:
Table of Contents

Advertisement

Field Service Ver. 1.0 Jun. 2008
MODE
Bit:
024
Bit
Feature
7
TX forwarding to adminis-
trator. <*>
6
TX forwarding of scanner
function to administrator.
<*>
5
Report output when TX
forwarding to administra-
4
tor is set. <*>
2
Select ID display order
when receiving.
1
0
Receive by memory.
NOTE
• The features with (*) are settable by users. <*>: Soft switch setting
MODE
Bit:
025
Bit
Feature
7
Memory overflow
transmission mode
6
Factory setting bit
7 6 5 4
3 2 1 0
1 1 0 1
0 0 0 1
Logic
0
Disable
Enable
Disable
Enable
Bit 5-4:
00
01
10
11
Bit 2-1:
00
01
Others
No
Yes
Factory setting bit
7 6 5 4
3 2 1 0
0 1 0 0
0 0 0 0
Logic
0
Bit 7-6:
00
01
10
11
HEX: D1
Description
1
Valid when Mode 024 Bit 7 is set to
"Enable."
Not output
Output when
TX fails
Always output
Not available
Expansion ID
Determine the subject
→ TSI
data priority displayed in
the subject line for gate-
TSI
way transmission (*)
Not available
when Report, Screen
display and Network
options are set to Yes.
(*)
When forward is speci-
fied in the user's "Docu-
ment management"
settings, and received
facsimile is broadcast
via E-mail.
HEX: 40
Description
1
Quit transmission
Inquire (Quit TX for non-response
and quick memory TX)
Inquire (Continue TX for non-response
and quick memory TX)
Not available
8. Soft Switch
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents