6. Malfunction code
6.2

Solution

6.2.1

C1004: FNS communication error

JS control board (JSCB)
Step
Disconnect and then connect the power
cord. Turn OFF the main power switch, wait
1
for 10 sec. or more, and turn ON the main
power switch.
Rewrite firmware using the compact flash
2
card.
3
Change JSCB
6.2.2

C1182: Shift motor drive failure

Shift motor (M2)
Shift home sensor (PS6)
Step
Check the M2 connector for proper con-
1
nection and correct as necessary.
Check the connector of M2 for proper
2
drive coupling and correct as necessary.
3
PS6 I/O check, sensor check
4
M2 operation check
5
Change JSCB
24
Relevant electrical parts
Action
Relevant electrical parts
Action