Error Code Description
4509 248B Memory subsystem and memory tests detected
fault in operator panel
4509 25C0 Memory subsystem and memory tests detected
fault in system backplane
4509 25C1 Memory subsystem and memory tests detected
fault in 1.0 GHz clock card
4509 25D9 Memory subsystem and memory tests detected
fault in L3 VPD card used with 1.1 GHz MCM
and 1.3 GHz MCM
4509 25E7 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4509 25E8 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4509 25F1 Memory subsystem and memory tests detected
fault in L3 VPD card used with 1.3 GHz MCM
4509 25F9 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4509 269A Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4509 28B0 Memory subsystem and memory tests detected
fault in I/O subsystem PCI backplane
4509 28B1 Memory subsystem and memory tests detected
fault in I/O subsystem DASD backplane
4509 302A Memory subsystem and memory tests detected
fault in 8 GB memory book (inner)
4509 302B Memory subsystem and memory tests detected
fault in 8 GB memory book (outer)
4509 302C Memory subsystem and memory tests detected
fault in 32 GB memory book (inner)
4509 302D Memory subsystem and memory tests detected
fault in 32 GB memory book (outer)
4509 305A Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(inner)
4509 305B Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(outer)
4509 305C Memory subsystem and memory tests detected
fault in 4 GB inner memory book
4509 305D Memory subsystem and memory tests detected
fault in 4 GB outer memory book
4509 305E Memory subsystem and memory tests detected
fault in 16 GB inner memory book
4509 305F Memory subsystem and memory tests detected
fault in 16 GB outer memory book
678
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Operator panel
Location: U1.17-L1
System backplane
Location: U1.18-P1
Clock card
Location: U1.18-P1-X5
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.