Error Code Description
4504 25E8 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4504 25F1 Memory subsystem and processor subsystem
tests detected fault in L3 VPD card used with
1.3 GHz MCM
4504 25F9 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4504 269A Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4504 28B0 Memory subsystem and processor subsystem
tests detected fault in I/O subsystem PCI
backplane
4504 28B1 Memory subsystem and processor subsystem
tests detected fault in I/O subsystem DASD
backplane
4504 302A Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(inner)
4504 302B Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(outer)
4504 302C Memory subsystem and processor subsystem
tests detected fault in 32 GB memory book
(inner)
4504 302D Memory subsystem and processor subsystem
tests detected fault in 32 GB memory book
(outer)
4504 305A Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(inner)
4504 305B Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(outer)
4504 305C Memory subsystem and processor subsystem
tests detected fault in 4 GB inner memory book
4504 305D Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
4504 305E Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
4504 305F Memory subsystem and processor subsystem
tests detected fault in 16 GB outer memory
book
4504 307A Memory subsystem and processor subsystem
tests detected fault in 4 GB inner memory book
4504 307B Memory subsystem and processor subsystem
tests detected fault in 8 GB inner memory book
4504 307C Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
Action/
Possible Failing FRU
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327 to isolate the failing
component.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329 to isolate the failing
component.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327 to isolate the failing
component.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329 to isolate the failing
component.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Chapter 5. Error Code to FRU Index