Step 152m-29
Is the error code recorded in "Step 152m-1" on page 291 of the form 101A xxxx or 101B xxxx?
Yes
Go to "Step 152m-12" on page 292.
No
All system partitions must be shut down and the system must be powered off to correct the power
cabling. Schedule nonconcurrent service with the customer to correct the power cabling. This ends
this procedure.
Step 152m-30
Is the error code recorded in "Step 152m-1" on page 291 of the form 101A xxxx or 101B xxxx?
Yes
Go to "Step 152m-6" on page 291.
No
Verify all power subsystem UPIC connections. Go to "Step 152m-31".
Step 152m-31
Are all power subsystem UPIC connections properly seated and correctly connected?
Yes
Call for support.
No
All system partitions must be shut down and the system must be powered off to correct the power
cabling. Schedule nonconcurrent service with the customer to correct the power cabling. This ends
this procedure.
294