Step 152l-36
Turn on the power.
Step 152l-37
Did the system stop with the same error code as recorded in "Step 152l-1" on page 284?
Yes
Go to "Step 152l-43".
No
Go to "Step 152l-38".
Step 152l-38
One of the cards just removed is defective.
Turn off the power.
Make sure all the green "power good out" LEDs of both I/O subsystem DCAs are off.
Step 152l-39
Reinsert one of the cards that is removed and listed in "Step 152l-35" on page 287.
Step 152l-40
Turn on the power.
Step 152l-41
Did the system stop with the same error code as recorded in "Step 152l-1" on page 284?
Yes
The card just reinserted is defective. Replace it. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152l-42".
Step 152l-42
Have all the cards listed in "Step 152l-35" on page 287 been reinserted?
Yes
The symptom has changed. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152l-39".
Step 152l-43
Turn off the power.
Examine the green "power good out" LEDs of both I/O subsystem DCAs.
288
Eserver pSeries 690 Service Guide