IBM pSeries 690 Service Manual page 427

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
1015 6014 Overcurrent or overvoltage problem with 3.3V in
second I/O subsystem
1015 6024 Overcurrent or overvoltage problem with 5.0V in
second I/O subsystem
1015 6034 Overcurrent or overvoltage problem with 2.5V in
second I/O subsystem
1015 6044 Overcurrent or overvoltage problem with 12.0V
in second I/O subsystem
1015 6054 Overcurrent or overvoltage problem with -12.0V
in second I/O subsystem
1015 6814 Overcurrent or overvoltage problem with 3.3V in
second I/O subsystem
1015 6824 Overcurrent or overvoltage problem with 5.0V in
second I/O subsystem
1015 6834 Overcurrent or overvoltage problem with 2.5V in
second I/O subsystem
1015 6844 Overcurrent or overvoltage problem with 12.0V
in second I/O subsystem
1015 6854 Overcurrent or overvoltage problem with -12.0V
in second I/O subsystem
1015 7017 Problem with fan 3 in second I/O subsystem in
primary rack
1015 7027 Problem with fan 4 in second I/O subsystem in
primary rack
1015 7117 Problem with fan 1 and fan 3 in second I/O
subsystem in primary rack
1015 7127 Problem with fan 2 and fan 4 in second I/O
subsystem in primary rack
1015 B014 Overcurrent or overvoltage problem with 3.3V in
second I/O subsystem
1015 B024 Overcurrent or overvoltage problem with 5.0V in
second I/O subsystem
1015 B034 Overcurrent or overvoltage problem with 2.5V in
second I/O subsystem
1015 B044 Overcurrent or overvoltage problem with 12.0V
in second I/O subsystem
1015 B054 Overcurrent or overvoltage problem with -12.0V
in second I/O subsystem
Action/
Possible Failing FRU
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
1. DCA-1
Location: U1.5-V1
2. Fan 3
Location: U1.5-F3
1. DCA-2
Location: U1.5-V2
2. Fan 4
Location: U1.5-F4
1. DCA-1
Location: U1.5-V1
2. Fans 1 and 3
Location: U1.5-F1 and U1.5-F3
1. DCA-2
Location: U1.5-V2
2. Fans 2 and 4
Location: U1.5-F2 and U1.5-F4
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Chapter 5. Error Code to FRU Index
407

Advertisement

Table of Contents
loading

Table of Contents