Error Code Description
4066 0C12 Mismatch between MCM 1 and VPD card
4066 0C13 Mismatch between MCM 3 and VPD card
4066 0CA5 Scan interface basic assurance tests detected
invalid processor subsystem configuration
4066 0CA6 Scan interface basic assurance tests detected
no usable main storage
4066 0CA9 Scan interface basic assurance tests detected
configuration error with processor memory
4066 0D00 Scan interface basic assurance tests detected
fault in L3 cache module 0
4066 0D01 Scan interface basic assurance tests detected
fault in L3 cache module 1
4066 0D02 Scan interface basic assurance tests detected
fault in L3 cache module 2
4066 0D03 Scan interface basic assurance tests detected
fault in L3 cache module 3
4066 0D04 Scan interface basic assurance tests detected
fault in L3 cache module 4
4066 0D05 Scan interface basic assurance tests detected
fault in L3 cache module 5
4066 0D06 Scan interface basic assurance tests detected
fault in L3 cache module 6
4066 0D07 Scan interface basic assurance tests detected
fault in L3 cache module 7
4066 0D08 Scan interface basic assurance tests detected
fault in L3 cache module 8
4066 0D09 Scan interface basic assurance tests detected
fault in L3 cache module 9
4066 0D0A Scan interface basic assurance tests detected
fault in L3 cache module 10
4066 0D0B Scan interface basic assurance tests detected
fault in L3 cache module 11
4066 0D0C Scan interface basic assurance tests detected
fault in L3 cache module 12
4066 0D0D Scan interface basic assurance tests detected
fault in L3 cache module 13
4066 0D0E Scan interface basic assurance tests detected
fault in L3 cache module 14
4066 0D0F Scan interface basic assurance tests detected
fault in L3 cache module 15
526
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Plugging error with FRU kit
Location: U1.18-P1-C3 and U1.18-P1-H2.5
Plugging error with FRU kit
Location: U1.18-P1-C2 and U1.18-P1-H2.6
Verify that MCMs, memory books, and L3
modules are correctly configured.
Reboot the system in slow mode to isolate the
failure.
Reboot the system in slow mode to isolate the
failure.
L3 cache module 0 and L3 VPD card
Location: U1.18-P1-C6 and U1.18-P1-H2.1
L3 cache module 1 and L3 VPD card
Location: U1.18-P1-C7 and U1.18-P1-H2.1
L3 cache module 2 and L3 VPD card
Location: U1.18-P1-C11 and U1.18-P1-H2.1
L3 cache module 3 and L3 VPD card
Location: U1.18-P1-C10 and U1.18-P1-H2.1
L3 cache module 4 and L3 VPD card
Location: U1.18-P1-C8 and U1.18-P1-H2.1
L3 cache module 5 and L3 VPD card
Location: U1.18-P1-C20 and U1.18-P1-H2.1
L3 cache module 6 and L3 VPD card
Location: U1.18-P1-C16 and U1.18-P1-H2.1
L3 cache module 7 and L3 VPD card
Location: U1.18-P1-C12 and U1.18-P1-H2.1
L3 cache module 8 and L3 VPD card
Location: U1.18-P1-C19 and U1.18-P1-H2.1
L3 cache module 9 and L3 VPD card
Location: U1.18-P1-C18 and U1.18-P1-H2.1
L3 cache module 10 and L3 VPD card
Location: U1.18-P1-C14 and U1.18-P1-H2.1
L3 cache module 11 and L3 VPD card
Location: U1.18-P1-C15 and U1.18-P1-H2.1
L3 cache module 12 and L3 VPD card
Location: U1.18-P1-C17 and U1.18-P1-H2.1
L3 cache module 13 and L3 VPD card
Location: U1.18-P1-C5 and U1.18-P1-H2.1
L3 cache module 14 and L3 VPD card
Location: U1.18-P1-C9 and U1.18-P1-H2.1
L3 cache module 15 and L3 VPD card
Location: U1.18-P1-C13 and U1.18-P1-H2.1