Table 2. Firmware Checkpoints (continued)
Checkpoint
E53D
E540
E541
E544
E545
E546
E547
E548
E549
376
Eserver pSeries 690 Service Guide
Description
Disable the anynode mode
Begin initialization of I/O subsystem
Initialize the routing table
Enable the I/O ports
Set up the device routing address for this
new node ID
Set up the I/O interface chip new node ID
Set up the I/O interface chip routing table
Disable any node mode
Adjust I/O hub table
Action/
Possible Failing FRU
Replace the I/O subsytem backplane that
the RIO cable specified by the location
code is attached to.
1.
Check for system firmware updates.
2. Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
3. Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O book that the failing I/O
subsystem is attached to, U1.18-P1-Hx.
3. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.