Error Code Description
4067 0BF8 Bus tests detected fault in I/O hub chip 8 (port
x)
4067 0BF9 Bus tests detected fault in I/O hub chip 9 (port
x)
4067 0BFA Bus tests detected fault in I/O hub chip 10 (port
x)
4067 0BFB Bus tests detected fault in I/O hub chip 11 (port
x)
4067 0BFC Bus tests detected fault in I/O hub chip 12 (port
x)
4067 0BFD Bus tests detected fault in I/O hub chip 13 (port
x)
4067 0C03 Bus tests detected fault in all MCMs
4067 0C09 Bus tests detected fault in all memory books
4067 0C0A Bus tests detected fault in all I/O books
4067 0C10 Bus tests detected mismatch between MCM 0
and VPD card
4067 0C11 Bus tests detected mismatch between MCM 2
and VPD card
Action/
Possible Failing FRU
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H1/Q7
b. U1.18-P1-H1/Q8
2. Replace the RIO book,
Location: U1.18-P1-H1
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H1/Q5
b. U1.18-P1-H1/Q6
2. Replace the RIO book,
Location: U1.18-P1-H1
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H3/Q3
b. U1.18-P1-H3/Q4
2. Replace the RIO book,
Location: U1.18-P1-H3
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H3/Q1
b. U1.18-P1-H3/Q2
2. Replace the RIO book,
Location: U1.18-P1-H3
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H4/Q1
b. U1.18-P1-H4/Q2
2. Replace the RIO book,
Location: U1.18-P1-H4.
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H4/Q3
b. U1.18-P1-H4/Q4
2. Replace the RIO book,
Location: U1.18-P1-H4
Go to "MAP 1543: MCM Module Problem
Isolation" on page 325.
Go to "MAP 1546: Memory Book Problem
Isolation" on page 331.
Go to "MAP 1547: I/O Book Problem Isolation"
on page 333.
Plugging error with FRU kit
Location: U1.18-P1-C1 and U1.18-P1-H2.3
Plugging error with FRU kit
Location: U1.18-P1-C4 and U1.18-P1-H2.4
Chapter 5. Error Code to FRU Index