Error Code Description
20EE 0003 IP parameter requires 3 dots "."
20EE 0004 Invalid IP parameter
20EE 0005 Invalid IP parameter (>255)
20EE 0007 Keyboard not found
20EE 0008 No configurable adapters found in the system
by the remote IPL menu in the SMS utilities
20EE 0009 Unable to communicate with the service
processor
20EE 000A The image size on the boot or installation
device exceeds the system firmware memory
limitations.
20EE 000B The system was not able to find an operating
system on the devices in the boot list.
468
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid IP parameter.
Example: 255.192.002.000
1. Plug in keyboard.
2. Replace the USB card the keyboard is
plugged into.
This error occurs when the remote IPL menu
in the SMS utilities cannot locate any LAN
adapters that are supported by the remote IPL
function. If a supported device is installed:
1. Replace the adapter. (See notes on page
391.)
2. Replace the I/O subsystem backplane in
the subsystem(s) containing the
device/adapter.
Replace the primary I/O book,
Location: U1.18-P1-H2
1. Check for system firmware updates. Apply
if available.
2. Call service support.
Go to "Boot Problems" on page 388.