IBM pSeries 690 Service Manual page 499

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
2601 0000 Boot failed because the RIO cables, or the
power subsystem cables, are not routed
correctly to the I/O subsystems
2601 0001 Boot failed because the I/O subsystem has
not been programmed correctly.
2601 0002 RIO cable error or DCA power cable error
detected on an I/O subsystem
2602 0001 Invalid PCI adapter vendor ID
Action/
Possible Failing FRU
1. Check both ends of the RIO cable
specified in the location code that appears
with this error code.
2. Determine which I/O subsystem is at the
end of the RIO cable specified by the
location code shown with this error code.
Check both ends of the power cables
going to both DCAs in that I/O subsystem.
For information about I/O cabling and
connector locations, see "I/O Book Connector
Locations" on page 22 and "Subsystem
Positioning and Cabling" on page 39.
Note: The port location code identifies the I/O
book number.
For information about I/O book cabling and
connector locations, see "I/O Book Connector
Locations" on page 22 and "Subsystem
Positioning and Cabling" on page 39.
1. Ensure that power cables are correctly
connected to drawers.
2. Firmware, including power code, may
have to be flashed on both sides of the
I/O subsystem.
Note: The location code identifies the I/O
subsystem that has the problem
3. Contact the next level of support.
1. Check both ends of the RIO cable
specified in the location code that appears
with this error code.
2. Determine which I/O subsystem is at the
end of the RIO cable specified by the
location code shown with this error code.
Check the power cables going to both
DCAs in that I/O subsystem.
For information about I/O cabling and
connector locations, see "I/O Book Connector
Locations" on page 22 and "Subsystem
Positioning and Cabling" on page 39.
Note: The port location code identifies the I/O
book number.
1. Move adapter to another slot (behind a
different PCI bus).
2. Check for available firmware updates for
adapter. Apply update if available.
3. Run AIX diagnostics on adapter. Replace
if indicated.
4. Replace adapter.
5. Check for system firmware updates. Apply
if update available.
6. Replace I/O subsystem backplane (See
notes on Chapter 5, "Error Code to FRU
Index", on page 391.)
Chapter 5. Error Code to FRU Index
479

Advertisement

Table of Contents
loading

Table of Contents