IBM pSeries 690 Service Manual page 721

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
460C 273C I/O subsystem and IPL detected fault in primary
I/O book - Slot 0
460C 273D I/O subsystem and processor subsystem tests
detected fault in primary I/O book - Slot 0
460C 2776 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
460C 2806 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
460C 28B0 I/O subsystem and IPL detected fault in I/O
subsystem PCI backplane
460C 28B1 I/O subsystem and IPL detected fault in I/O
subsystem DASD backplane
460C 525E CUoD capacity card fault
460C 525F CUoD capacity card fault
460C 527A CUoD capacity card fault
460C 527C CUoD capacity card fault
460D 248B I/O subsystem and attention handler detected
fault in operator panel
Action/
Possible Failing FRU
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Primary I/O book - Slot 0
Location: U1.18-P1-H2
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
Operator panel
Location: U1.17-L1
Chapter 5. Error Code to FRU Index
701