IBM pSeries 690 Service Manual page 449

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
101B x835 Power cable fault
101B x925 Power cable fault
101B x935 Power cable fault
101B xA25 Power cable fault
101B xA35 Power cable fault
101B xx0x BPA B-FRU not isolated
101B xx11 BPA-B / BPC
101B xx13 Seeprom (VPD) fault on BPC-B
101B xx17 Fan fault on BPC-B (BPA-B fan)
101B xx21 BPA-B / BPD-1
101B xx22 BPC-B to BPD-1 communications fault
101B xx23 Seeprom (VPD) fault on BPD-1B
101B xx31 BPA-B / BPD-2
Action/
Possible Failing FRU
If there is no DCA in U1.18-P1-V8, go to "MAP
1520: Power" on page 190 with these location
codes:
U1.35-P2-X3/Q8# to U1.13-V2/Q1#
If there is a 6th DCA in U1.18-P1-V8, this error
code will not be reported.
Go to "MAP 1520: Power" on page 190 with
these location codes:
U1.35-P2-X3/Q9# to U1.18-P1-V5/Q2#
If there is no DCA in U1.18-P1-V8, go to "MAP
1520: Power" on page 190 with these location
codes:
U1.35-P1-X2/Q9# to U2.19-V1/Q2#
If there is a 6th DCA in U1.18-P1-V8, go to
"MAP 1520: Power" on page 190 with these
location codes:U1.35-P2-X2/Q9# to
U1.13-V1/Q2#
Go to "MAP 1520: Power" on page 190 with
these location codes:
U1.35-P2-X3/Q10# to U1.18-P1-V6/Q2#
If there is no DCA in U1.18-P1-V8, go to "MAP
1520: Power" on page 190 with these location
codes:
U1.35-P1-X2/Q10# to U2.19-V2/Q2#
If there is a 6th DCA in U1.18-P1-V8, go to"MAP
1520: Power" on page 190 with these location
codes:
U1.35-P2-X2/Q10# to U1.13-V2/Q2#
U1.35
U1.35-P2-X4
U1.35-P2-X4
1. BPE-B side fan
Location: U1.35-P2-F1
2. BPC-B
Location: U1.35-P2-X4
U1.35-P2-X3
1. BPD-1
Location: U1.35-P2-X3
2. BPC-B
Location: U1.35-P2-X4
3. BPE backplane B
Location: U1.35-P2
U1.35-P2-X3
U1.35-P2-X2
Chapter 5. Error Code to FRU Index
429

Advertisement

Table of Contents
loading

Table of Contents