Table 2. Firmware Checkpoints (continued)
Checkpoint
E52F
E530
E531
E532
E533
E534
374
Eserver pSeries 690 Service Guide
Description
End of configuration of the RIO hub
Checking I/O hub ports on current I/O hub
Get I/O hub node ID
I/O cable detected; enable the I/O hub port
Set up the I/O hub routing table
Get the node ID of the node on the other
end of the I/O cable
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. Check for system firmware updates.
2. Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O book that the failing I/O
subsystem is attached to, U1.18-P1-Hx.
3. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
4. Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O book that the failing I/O
subsystem is attached to, U1.18-P1-Hx.
3. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
4. Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O book that the failing I/O
subsystem is attached to, U1.18-P1-Hx.
3. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
4. Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. This error code may indicate that the
I/O (RIO) cables are not properly
connected to the I/O subsystems.
Check the RIO cabling; refer to "I/O
Book Connector Locations" on page 22
and "Subsystem Positioning and
Cabling" on page 39.
2. Replace the RIO cable specified by the
location code.
3. Replace the I/O book that the failing I/O
subsystem is attached to, U1.18-P1-Hx.
4. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
5. Go to "MAP 1542: I/O Problem
Isolation" on page 306.