Table 2. Firmware Checkpoints (continued)
Checkpoint
E1F6
E1F7
E1F8
E1FA
E1FB
E1FC
E1FD
E1FE
E1FF
E20F
E440
E441
Description
Determine boot device sequence
No boot image located
Partition (system firmware) is waiting for a
virtual terminal to be opened on HMC.
Building boot device list for SCSI adapters.
(The device ID and the device LUN being
scanned code are also displayed.)
Scan SCSI bus for attached devices
Building boot device list for SSA adapters.
The location code of the SSA adapter being
scanned is also displayed.
The operator panel alternates between the
code E1FD and another Exxx code, where
Exxx is the point at which the error
occurred.
Building boot device list for fibre-channel
adapters. (The WWPN of the SAN adapter
being scanned is also displayed.)
Building boot device list for fibre-channel
adapters. (The WWPN of the SAN adapter
being scanned is also displayed.)
System firmware has exited to open
firmware prompt.
Validate NVRAM, initialize partitions as
needed
Generate /options node NVRAM
configuration variable properties
Action/
Possible Failing FRU
Go to "MAP 1542: I/O Problem Isolation" on
page 306.
Go to "Boot Problems" on page 388.
Open a virtual terminal for the partition on
the HMC.
If the partition hangs at this checkpoint after
a virtual terminal is opened on the HMC:
1. Replace the service processor/RIO
book, location: U1.18-P1-H2
2. Call service support.
1. If a location code is available, follow the
actions listed for error code 21A0 00xx.
2.
Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. If a location code is available, follow the
Repair actions listed for error code
21A0 00XX.
2. If no location code is available, go to
"MAP 1542: I/O Problem Isolation" on
page 306.
Go to "MAP 1542: I/O Problem Isolation" on
page 306.
1. If a location code is available, follow the
actions listed for error code 21A0 00xx.
2. If no location code is available, go to
"MAP 1542: I/O Problem Isolation" on
page 306.
Go to "MAP 1542: I/O Problem Isolation" on
page 306.
Go to "MAP 1542: I/O Problem Isolation" on
page 306.
1. Replace the primary I/O book,
Location: U1.18-P1-H2.
2. Call service support.
1. Check for system firmware updates.
2. Replace the primary I/O book,
Location: U1.18-P1-H2.
3. Call service support.
1. Check for system firmware updates.
2. Replace the primary I/O book,
Location: U1.18-P1-H2.
3. Call service support.