Error Code Description
406D 0EB9 Attention line 8 stuck fault
406D 0EBA Attention line 9 stuck fault
406D 0EBB Attention line 10 stuck fault
406D 0EBC Attention line 11 stuck fault
406D 0EBF Memory error
406D 0EE1 Attention handler detected fault in service
processor code (invalid MRU to mapping)
406D 0EE2 Attention handler detected fault in service
processor firmware fault
406D 0EE5 Attention handler detected firmware error; no
callout available
406D 25E6 SMA 4-port switch adapter fault
406D 273F SMA 2-port switch adapter fault
406E 0001 Scan control routineIPL detecteds detected
clock card assembly failure
406E 0002 Scan control routines detected backplane
assembly failure
406E 0003 Scan control routines detected fault in MCM
module 0
406E 0004 Scan control routines detected fault in MCM
module 2
406E 0005 Scan control routines detected fault in MCM
module 1
406E 0006 Scan control routines detected fault in MCM
module 3
626
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
1. Reboot the system in slow mode to the
SMS menus. See "Performing Slow Boot"
on page 391.
2. Examine the service processor error log.
v If a CEC subsystem error (a 4xxx yyyy
error) occurred during the slow boot that
calls out the memory, processors, L3
cache modules, or the primary I/O book,
replace the part indicated by the location
code.
v If a CEC subsystem error (a 4xxx yyyy
error) did not occur during the slow boot,
look for a 4xxx yyyy error immediately
preceding the 406x 0EBF error. Replace
the part indicated by the location code
associated with that error.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
Replace the I/O book (switch adapter) specified
by the location code.
Replace the I/O book (switch adapter) specified
by the location code.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
MCM module 0 and VPD card
Location: U1.18-P1-C1 and U1.18-P1-H2.3
MCM module 2 and VPD card
Location: U1.18-P1-C4 and U1.18-P1-H2.4
MCM module 1 and VPD card
Location: U1.18-P1-C3 and U1.18-P1-H2.5
MCM module 3 and VPD card
Location: U1.18-P1-C2 and U1.18-P1-H2.6