IBM pSeries 690 Service Manual page 672

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
406F 0C12 Error code generation/logging detected
mismatch between MCM 1 and VPD card
406F 0C13 Error code generation/logging detected
mismatch between MCM 3 and VPD card
406F 0CA5 Error code generation/logging detected invalid
processor subsystem configuration
406F 0CA6 Error code generation/logging detected no
usable main storage
406F 0CA9 Error code generation/logging detected
configuration error with processor memory
406F 0D00 Error code generation/logging detected fault in
L3 cache module 0
406F 0D01 Error code generation/logging detected fault in
L3 cache module 1
406F 0D02 Error code generation/logging detected fault in
L3 cache module 2
406F 0D03 Error code generation/logging detected fault in
L3 cache module 3
406F 0D04 Error code generation/logging detected fault in
L3 cache module 4
406F 0D05 Error code generation/logging detected fault in
L3 cache module 5
406F 0D06 Error code generation/logging detected fault in
L3 cache module 6
406F 0D07 Error code generation/logging detected fault in
L3 cache module 7
406F 0D08 Error code generation/logging detected fault in
L3 cache module 8
406F 0D09 Error code generation/logging detected fault in
L3 cache module 9
406F 0D0A Error code generation/logging detected fault in
L3 cache module 10
406F 0D0B Error code generation/logging detected fault in
L3 cache module 11
406F 0D0C Error code generation/logging detected fault in
L3 cache module 12
406F 0D0D Error code generation/logging detected fault in
L3 cache module 13
406F 0D0E Error code generation/logging detected fault in
L3 cache module 14
406F 0D0F Error code generation/logging detected fault in
L3 cache module 15
652
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Plugging error with FRU kit
Location: U1.18-P1-C3 and U1.18-P1-H2.5
Plugging error with FRU kit
Location: U1.18-P1-C2 and U1.18-P1-H2.6
Verify that MCMs, memory books, and L3
modules are correctly configured.
Reboot the system in slow mode to isolate the
failure.
Reboot the system in slow mode to isolate the
failure.
L3 cache module 0 and L3 VPD card
Location: U1.18-P1-C6 and U1.18-P1-H2.1
L3 cache module 1 and L3 VPD card
Location: U1.18-P1-C7 and U1.18-P1-H2.1
L3 cache module 2 and L3 VPD card
Location: U1.18-P1-C11 and U1.18-P1-H2.1
L3 cache module 3 and L3 VPD card
Location: U1.18-P1-C10 and U1.18-P1-H2.1
L3 cache module 4 and L3 VPD card
Location: U1.18-P1-C8 and U1.18-P1-H2.1
L3 cache module 5 and L3 VPD card
Location: U1.18-P1-C20 and U1.18-P1-H2.1
L3 cache module 6 and L3 VPD card
Location: U1.18-P1-C16 and U1.18-P1-H2.1
L3 cache module 7 and L3 VPD card
Location: U1.18-P1-C12 and U1.18-P1-H2.1
L3 cache module 8 and L3 VPD card
Location: U1.18-P1-C19 and U1.18-P1-H2.1
L3 cache module 9 and L3 VPD card
Location: U1.18-P1-C18 and U1.18-P1-H2.1
L3 cache module 10 and L3 VPD card
Location: U1.18-P1-C14 and U1.18-P1-H2.1
L3 cache module 11 and L3 VPD card
Location: U1.18-P1-C15 and U1.18-P1-H2.1
L3 cache module 12 and L3 VPD card
Location: U1.18-P1-C17 and U1.18-P1-H2.1
L3 cache module 13 and L3 VPD card
Location: U1.18-P1-C5 and U1.18-P1-H2.1
L3 cache module 14 and L3 VPD card
Location: U1.18-P1-C9 and U1.18-P1-H2.1
L3 cache module 15 and L3 VPD card
Location: U1.18-P1-C13 and U1.18-P1-H2.1

Advertisement

Table of Contents
loading