Error Code Description
460D 527A CUoD capacity card fault
460D 527C CUoD capacity card fault
460E 248B I/O subsystem and scan control routines
detected fault in operator panel
460E 25C0 I/O subsystem and scan control routines
detected fault in system backplane
460E 25C1 I/O subsystem and scan control routines
detected fault in 1.0 GHz clock card
460E 2738 I/O subsystem and scan control routines
detected fault in I/O book 1, 3, or 4
460E 273C I/O subsystem and scan control routines
detected fault in primary I/O book - Slot 0
460E 273D I/O subsystem and processor subsystem tests
detected fault in primary I/O book - Slot 0
460E 2776 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
460E 2806 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
460E 28B0 I/O subsystem and scan control routines
detected fault in I/O subsystem PCI backplane
460E 28B1 I/O subsystem and scan control routines
detected fault in I/O subsystem DASD
backplane
Action/
Possible Failing FRU
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
Operator panel
Location: U1.17-L1
System backplane
Location: U1.18-P1
Clock card
Location: U1.18-P1-X5
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Primary I/O book - Slot 0
Location: U1.18-P1-H2
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
Chapter 5. Error Code to FRU Index