Error Code Description
101A 0876 BPR 3A communications fault
101A 0D06 350 volt bulk failure, BPA-A
101A 1C06 Cage airflow missing (temperature problem)
101A 3F06 Invalid I/O subsystem configurations
101A 7A56 IBF failure
101A 7A66 IBF failure
101A 7A76 IBF failure
101A 7A86 IBF 1A failure
101A 7A96 IBF 2A failure
101A 7AA6 IBF 3A failure
101A 7B56 IBF failure
101A 7B66 IBF failure
101A 7B76 IBF failure
101A 7B86 IBF 1A failure
101A 7B96 IBF 2A failure
101A 7BA6 IBF 3A failure
101A CE16 BPC-BPC communication failure
101A D216 BPA-BPA communication failure
Action/
Possible Failing FRU
Go to "MAP 1523: There Is a Bulk Power
Regulator (BPR) Communications Fault" on
page 198.
Go to "MAP 1525: There Is a 350 Volt Bulk
Failure" on page 200.
Go to "MAP 1527: An Airflow Loss Has Been
Detected" on page 206.
1. Verify that the I/O subsystems are properly
cabled.
Note: If the service processor is hung, this
error code causes the service processor to
hang. Refer to "Resetting the Service
Processor" on page 804.
2. Call service support.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
1. Check the cable between the two BPCs;
reseat and look for bent pins.
2. Replace BPC-A, location: U1.35-P1-X4
3. Replace BPC-B, location: U1.35-P2-X4.
Go to "MAP 1520: Power" on page 190 for
isolation.