Table 2. Firmware Checkpoints (continued)
Checkpoint
E56F
E570
E571
E572
E57F
E580
E581
E582
E583
380
Eserver pSeries 690 Service Guide
Description
End initializing the service processor control
chip
Initialize the PCI-ISA bridge chip
Initialize the integrated Ethernet (if present) 1. Replace the I/O cable specified by the
Initialize the integrated SCSI
End of I/O interface chip initialization
Begin initializing the EADS module
Read the PCI bus configuration header
EADS has been detected
Running BIST on the current EADS
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Check for system firmware updates.
2. Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. Check for system firmware updates.
2. Go to "MAP 1542: I/O Problem
Isolation" on page 306.
1. This error code may indicate that the
I/O (RIO) cables are not properly
connected to the I/O subsystems.
Check the RIO cabling; refer to "I/O
Book Connector Locations" on
page 22and "Subsystem Positioning
and Cabling" on page 39.
2. Replace the RIO cable specified by the
location code.
3. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.