Error Code Description
4608 273C I/O subsystem and other bus tests detected
fault in primary I/O book - Slot 0
4608 273D I/O subsystem and processor subsystem tests
detected fault in primary I/O book - Slot 0
4608 2776 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
4608 2806 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
4608 28B0 I/O subsystem and other bus tests detected
fault in I/O subsystem PCI backplane
4608 28B1 I/O subsystem and other bus tests detected
fault in I/O subsystem DASD backplane
4608 525E CUoD capacity card fault
4608 525F CUoD capacity card fault
4608 527A CUoD capacity card fault
4608 527C CUoD capacity card fault
4609 248B I/O subsystem and memory tests detected fault
in operator panel
696
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Primary I/O book - Slot 0
Location: U1.18-P1-H2
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.