Error Code Description
20EE 000C Pointer to the operating system found in
non-volatile storage.
20EE 000E Unable to execute the lpar-mgr open firmware
method
20EE 000F Unable to find the lpar-mgr package node
20EE 0010 Unable to execute the root vpd method
Action/
Possible Failing FRU
Values normally found in non-volatile storage
that point to the location of an operating
system were not found. This can happen for
two reasons:
v Either your operating system doesn't
support storing the values
or
v An event occurred that caused the system
to lose non-volatile storage information
(drainage or replacement of the battery).
If you are running AIX, reconstruct this
information by running the bootlist command
and specifying the device that the operating
system is installed on. See the AIX
documentation for the syntax and usage of
the bootlist command. To boot the operating
system so that the above-mentioned values
can be reconstructed, power the system down
and power it back on again to cause the
system to look for the operating system in the
devices contained in the custom boot list or in
the default boot list, depending on the
condition of the system. If this is not
successful, use the SMS menus to modify the
boot sequence (also known as the boot list) to
include devices that are known to contain a
copy of the operating system. For example,
select a hard disk known to have a copy of
the operating system as the first and only
device in the boot sequence and attempt to
boot again. If the problem persists, replace
the primary I/O book,
Location: U1.18-P1-H2
1. Verify that the system is in LPAR mode,
and reboot the system.
2. Reflash the system with the latest level of
system firmware.
3. Call service support.
1. Verify that the system is in LPAR mode,
and reboot the system.
2. Reflash the system with the latest level of
system firmware.
3. Call service support.
1. Verify that the system is in LPAR mode,
and reboot the system.
2. Reflash the system with the latest level of
system firmware.
3. Call service support.