Error Code Description
B1xx 4633
Cont'd
B1xx 4634 SPCN Loop Fault
B1xx 4635 AC input was removed, then restored.
B1xx 4636 System is running on battery back-up power
B1xx 4643 Problem when turning on the identify LED of a
FRU
B1xx 4644 I2C connection failure
B1xx 4645 I2C (non-processor) VPD system fault
B1xx 4646 Vital product data (VPD) acquisition failure
B1xx 4647 Machine type and model fields missing or
invalid in system VPD
B1xx 4648 Processor subsystem backplane VPD or power
source problem
B1xx 4650 System processor failure (all processors reset).
B1xx 4651 CPU GARD VPD on MCM 0
732
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
1. Wait 10 minutes after the system has
reached the AIX prompt. Examine the AIX
error log for new B1xx 4633 errors with the
word 13 values (in bytes 68 and 69 in the
error log entry). If there are no B1xx 4633
errors with matching time stamps, the
SPCN down load was successful. If the
download failed again (there is another
B1xx 4633 error in the AIX error log with the
correct time stamp), do the following:
a. Power down the system.
b. Collect the service processor error log
data for the B1xx 4633 error (see 2 on
page 731).
c. Collect the SPCN trace data (see 3 on
page 731).
d. Contact service support. For all other
values of word 13, or bytes 68 and 69,
do the following:
1) Check for system firmware updates.
Apply if available.
2) Call service support.
1. Check SPCN cabling.
2. Go to "MAP 1542: I/O Problem Isolation" on
page 306.
Informational message. Look at the service
processor error log for additional error codes
relating to loss of ac power to the system.
Informational message.
1. Use the location code that was provided
with the original error code to isolate and
replace the failing device.
2. If a problem persists, go to "MAP 154A: I2C
Bus Problem Isolation" on page 346.
1. Check for system firmware updates.
2. Primary I/O book
Location: U1.18-P1-H2
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
1. Check for system firmware updates.
2. Primary I/O book
Location: U1.18-P1-H2
The machine type and model fields must be
rewritten. Call service support.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Reboot the system in slow mode to isolate the
problem.
U1.18-P1-C1 and U1.18-P1-H2.3