Error Code Description
101A xxB1 BPA-A / EPO_SW
101B 0856 BPR 1B communications fault
101B 0866 BPR 2B communications fault
101B 0876 BPR 3B communications fault
101B 0D06 350 volt bulk failure, BPA-B
101B 1C06 Cage airflow missing (temperature problem)
101B 3F06 Invalid I/O subsystem configuration
101B 7A56 IBF failure
101B 7A66 IBF failure
101B 7A76 IBF failure
101B 7A86 IBF 1B failure
101B 7A96 IBF 2B failure
101B 7AA6 IBF 3B failure
101B 7B56 IBF failure
101B 7B66 IBF failure
101B 7B76 IBF failure
101B 7B86 IBF 1B failure
101B 7B96 IBF 2B failure
101B 7BA6 IBF 3B failure
424
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
1. Replace the UEPO switch,
Location: U1-V1
2. Check the cable from BPC-A to the UEPO
switch,
Location U1-V1/Q1#
Go to "MAP 1523: There Is a Bulk Power
Regulator (BPR) Communications Fault" on
page 198.
Go to "MAP 1523: There Is a Bulk Power
Regulator (BPR) Communications Fault" on
page 198.
Go to "MAP 1523: There Is a Bulk Power
Regulator (BPR) Communications Fault" on
page 198.
Go to "MAP 1525: There Is a 350 Volt Bulk
Failure" on page 200.
Go to "MAP 1527: An Airflow Loss Has Been
Detected" on page 206.
1. Verify that the I/O subsystems are properly
cabled.
Note: If the service processor is hung, this
error code causes the service processor to
hang. Refer to "Resetting the Service
Processor" on page 804.
2. Call service support.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.
Go to "MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure" on page 203.