Error Code Description
2602 0002 Invalid PCI adapter device ID
2602 0007 PCI device I/O or memory space request
could not be satisfied
2602 0008 PCI device Fcode evaluation error
480
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
1. Move adapter to another slot (behind a
different PCI bus).
2. Check for available firmware updates for
adapter. Apply update if available.
3. Run AIX diagnostics on adapter. Replace
if indicated.
4. Replace adapter.
5. Check for system firmware updates. Apply
if update available.
6. Replace I/O subsystem backplane. (See
notes on Chapter 5, "Error Code to FRU
Index", on page 391.)
1. If the location code identifies a slot:
a. Reseat the adapter and reboot the
system.
b. Replace the adapter.
c. Check for system firmware updates.
Apply if available.
d. Replace the I/O backplane in which
the adapter is installed.
2. If the location code identifies an I/O
planar:
a. Check for system firmware updates.
Apply if available.
b. Replace the I/O backplane.
3. Call service support.
1. If the location code identifies a slot:
a. Check for adapter firmware updates.
Apply if available.
b. Replace the adapter.
c. Check for system firmware updates.
Apply if available.
2. If the location code identifies an I/O
planar:
a. Check for system firmware updates.
Apply if available.
b. Replace the I/O planar.
3. Call service support.