Error Code Description
4066 0BF8 Scan interface basic assurance tests detected
fault in I/O hub chip 8 (port x)
4066 0BF9 Scan interface basic assurance tests detected
fault in I/O hub chip 9 (port x)
4066 0BFA Scan interface basic assurance tests detected
fault in I/O hub chip 10 (port x)
4066 0BFB Scan interface basic assurance tests detected
fault in I/O hub chip 11 (port x)
4066 0BFC Scan interface basic assurance tests detected
fault in I/O hub chip 12 (port x)
4066 0BFD Scan interface basic assurance tests detected
fault in I/O hub chip 13 (port x)
4066 0C03 Scan interface basic assurance tests detected
fault in all MCMs
4066 0C09 Scan interface basic assurance tests detected
fault in all memory books
4066 0C0A Scan interface basic assurance tests detected
fault in all I/O books
4066 0C10 Mismatch between MCM 0 and VPD card
4066 0C11 Mismatch between MCM 2 and VPD card
Action/
Possible Failing FRU
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H1/Q7
b. U1.18-P1-H1/Q8
2. Replace the RIO book,
Location: U1.18-P1-H1
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H1/Q5
b. U1.18-P1-H1/Q6
2. Replace the RIO book,
Location: U1.18-P1-H1
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H3/Q3
b. U1.18-P1-H3/Q4
2. Replace the RIO book,
Location: U1.18-P1-H3
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H3/Q1
b. U1.18-P1-H3/Q2
2. Replace the RIO book,
Location: U1.18-P1-H3
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H4/Q1
b. U1.18-P1-H4/Q2
2. Replace the RIO book,
Location: U1.18-P1-H4.
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H4/Q3
b. U1.18-P1-H4/Q4
2. Replace the RIO book,
Location: U1.18-P1-H4
Go to "MAP 1543: MCM Module Problem
Isolation" on page 325.
Go to "MAP 1546: Memory Book Problem
Isolation" on page 331.
Go to "MAP 1547: I/O Book Problem Isolation"
on page 333.
Plugging error with FRU kit
Location: U1.18-P1-C1 and U1.18-P1-H2.3
Plugging error with FRU kit
Location: U1.18-P1-C4 and U1.18-P1-H2.4
Chapter 5. Error Code to FRU Index